04-ANNEXURES



FORM A (Form of Application)
(Rule -----)

From To

The Chief Administrator, Chandigarh.

Sir,

I/ We apply for permission to erect/re-erect/add/alter a building/ wall in accordance with the plans Submitted herewith on the Plot No. _____ in the layout of Sector No. ________. 2. I/We attach:

(a) A site plan showing the position of the plot proposed to be built Upon required by the rules;

(b) Plans, elevations and sections in triplicate as required by the rules;

(c) Drainage plans, engineering drawings (structural) as required by the rules;

(d) Specification of the proposed building;

(e) Copy of Allotment letter;

(f) Copy of Possession letter;

(g) Copy of letter showing extension in time limit for the construction of building.

(h) Copy of Power of Attorney, if the plans are submitted by the Attorney. (i) Affidavit and Indemnity Bond;

(j) Exemption under the Urban Land (Ceiling and Regulation) Act, 1976, if the area of the plot/ proposed covered areas are not within the prescribed limits of the said Act.

(k) Copy of the receipt for the Building Plan Security;

3. The construction of the building shall be supervised by ______Architect/ Structural Engineer as the case may be.

Dated Signature(s) Enclosures:

Received the Building Plans and documents as above on ………..The Plans may be collected from this office after 6 weeks from this date.

Receipt Clerks

For Estate Officer, Chandigarh

FORM B (Rule ---)

Form for Sanction

From The Chief Administrator,

Chandigarh. To Memorandum No……………… Dated, the

Reference your application for permission to erect/ re-erect/add to alter building on plot No. ………. In accordance with the plans submitted with it, your application is hereby: 

(i) Sanctioned for the aforesaid construction under rule ---- of the Punjab Capital (Development and Regulation) Building Rules, 1952.

(ii) Rejected for reasons given below.

Chief Administrator Chandigarh

FORM C (Rule -----Specifications

The materials to be used in the construction to be clearly specified under the following heads:

Items Specification

(a) Foundations

(b) Walls

(c) Damp-Proof Course

(d) Floors

(e) Roofs

(f) Windows and Doors and other Woodwork

(g) Steel work

(h) Internal Finish

(i) External Finish.

Signature of Applicant Signature of Architect

FORM D (Rule ----)

Notice of Completion/ Permission to Occupy and for grant of permission for Sewer Connection. From To

Chief Administrator, Chandigarh. Sir,

I/ We hereby give you notice that the building described below and a part of the building sanctioned with your order No. ______ dated ______ has been completed on ____ in all respects according to the sanctioned plans and the suggested modifications have been carried out.

1. Completion certificate from the Architect who supervised the sanitary installation works of the building is submitted herewith.

2. Certificate from the Licensed Plumber who supervised the sanitary installation works of the building is also submitted herewith.

3. Kindly grant permission for sewerage connection and permit me/us to occupy the building/ part of building as required under rule ---- of the Punjab Capital (Development and Regulation) Building Rules, 1952.

Description of Building

Sector Sub Sector

Plot No. House No.

( if any) Signature of Applicant

FORM E (Rule------)

Completion Certificate by an Architect.

I do hereby certify that the following work ______ (insert full particulars of work)

has been supervised by me and has been completed to the satisfaction in accordance with the sanctioned plan,

that the workmanship and the whole of the materials used are good, that no provisions of the Punjab Capital (Development and Regulation) Act, 1952, or the Building Rules made there under and no requisition made, conditions prescribed or order issued there under has been transgressed in the course of the work. A certificate of the Licensed Plumber duly verified is attached. Sector Sub-Sector

Plot No House No. (if any)

Particulars of work _____

Date:Signature (Architect)

FORM F (Rule------)

Permission for occupancy or use of the building and grant of sewer connection From

The Chief Administrator,

Chandigarh. To Memorandum No. Dated Whereas -------------- has given notice of completion of the building described below, I hereby:i) Grant permission for sewer connection.

ii) Grant permission for the occupation and/or use of the said building. OR

Refuse permission for the sewer connection/occupation of the said building for reasons given below:Description of Building, Sector Sub Sector

Plot No. House No. (if any)

Chief Administrator, Dated

Chandigarh

FORM G (Rule -----)

Application for Grant of License to work as a Plumber

To The Chief Administrator, Chandigarh. Sir, I apply for the issue/renewal of licence to work as Plumber at Chandigarh as required under rule --- of

the Punjab Capital (Development and Regulation) Building Rules, 1952. Detailed particulars are given below

1. Name

2. Address

3. Father's name

4. Date of Birth

5. Educational Qualification

6. Particulars of Experience

7. Have you held a licence for doing plumbing work previously in Chandigarh. If answer is "Yes", give particulars of the same in the following form:

(i) Number

(ii) Year

(iii) Period of commencement/expiry

(iv) Was it ever cancelled/suspended, if so, give particulars.

I solemnly declare that the information given above is correct.

Dated Signature of applicant

FORM H (Rule ---)

Chandigarh Administration

Plumber Licence No. ---------- of 20

 In pursuance of the provisions of the Rule ---- of the Punjab Capital (Development and Regulation)
Building Rules, 1952, the Chief Administrator, Chandigarh hereby grants a licence to Shri ______ or renews the licence of _____ to work as plumber in Chandigarh City.

2. This licence, unless revoked earlier, shall be valid upto 31st day of March, 20____ . Dated, Chandigarh, the Chief Administrator

Chandigarh

FORM I (Rule -----)

I do hereby certify that the following work………. (insert full particulars of work) has been supervised

by me and has been completed to my satisfaction in accordance with the sanctioned plan, that the workmanship

and the whole of the material used are good, that no provision of the Punjab Capital (Development and regulation)

Act, 1952 or the Building Rules, made there under and no requisition made, conditions prescribed or order issued

there under has been transgressed in the course of the work.

Sector Sub-Sector

Plot No. House No

(if any) Dated Signature

(Licensed Plumbing)

FORM J (Rule ----)

Certificate: To be submitted alongwith the building plans/drawings

1. Certified that the building plans submitted for approval satisfy the safety requirements as stipulated under Rule 40 of the Punjab Capital (Development and Regulation) Building Rules, 1952 and the information given therein is factually correct to the best of our knowledge and understanding.

2. It is also certified that the structural design safety requirement for all situations including safety from natural hazards based on soil conditions and Earthquake has been duly incorporated in the design of

the building and these provisions shall be adhered to during construction.

Signature of the  Owner with date

ignature of Structural Architect

Block Name in Block Letters/Address Letters

FORM K (Rule----)

Certificate: To be submitted at the time of obtaining Completion Certificate

1. Certified that the building (s) has been constructed according to the Sanctioned Plan and Structural design (one set of structural drawings as executed is enclosed) which incorporates the provision of structural safety as specified in revised plans submitted for approval satisfy the safety requirements as specified in part-6- Structural Design of NBC and other relevant Rules/Standards/Guidelines.

2. It is also certified that construction has been done under our supervision and guidance and adheres to the drawings submitted and the records of supervision has been maintained by us.

3. Any subsequent change from the completion drawings will be the responsibility of the owner (s). Signature of the Signature of Signature of Structural

Owner with date Architect with Engineer with date Date

(As defined in NBC of India)

Name in Block Name in Block Name in Block

Letters and Address Letters and Address Letters and Address.

ANNEXURE - 2

Solar Photo Voltaic Power Plant Notification

The installation of Solar Photo Voltaic Power Plant mandatory for residential and non residential buildings in Chandigarh.
 

Sr.
No.
Category Capacity of SPV plant (in kilo watt peak)
1. Residential Building i. 500 sq. Yd. To 999 sq. Yd.  -              1 (KWp) SPV
ii. 1000 sq. Yd. To 2999 sq. Yd.  - 2          (KWp) SPV
iii.  3000 sq. Yd. & above                  -   3  (KWp) SPV
2. All      private       Educational           Institutes, Schools,               Colleges,                   Hostels,
Technical/Vocational                         Education Institute,        Universities        etc.         having connected load of 30 kilo watt (KW) and
above
Minimum  5  Kilo  watt  peak  (KWp)  Or  5%  of connected load, whichever is higher.
3. All       Government Buildings  and         offices and  Govt.  Colleges,  Govt.  Educational Institutions,          ,     Universities         having connected load of 30 kilo watt (KW) and
above
Minimum  2  Kilo  watt  peak  (KWp)  Or  5%  of connected load, whichever is higher.
4. All   private   Hospitals   and   Nursing Homes,         Industrial              Establishments, Commercial        Establishments,            Malls, Hotels,   Motels,   Banquet   Halls   and Tourism          complexes,  having    connected load of
i) 50 kilo watt (KW) to 1000 Kilo Watt
(KW)
ii) above 1000 Kilo Watt (KW)
i) Minimum 10 Kilo watt peak (KWp)              Or 5% of connected load, whichever is higher.
ii) Minimum 50 Kilo watt peak (KWp)             Or 3% of connected load, whichever is higher.
5. All new Buildings to be constructed by Housing      Complexes,             developed   by Group      Housing         Societies,       Builder, Housing Boards, on a plot size of :
i) 0.5 Acre to 1.0 Acre;
ii) More than 1.0 Acre to 2.0 Acres;
iii) More than 2.0 Acre to 5.0 Acres;
iv) More than 5.0 Acres;
i)  Minimum 10 Kilo watt peak (KWp)
ii)  Minimum 20 Kilo watt peak (KWp)
iii) Minimum 30 Kilo watt peak (KWp)
iv) Minimum 40 Kilo watt peak (KWp)

NOTE

Height of the module structure carrying solar panels shall not be counted towards the total height of the building as permitted by building Rules.

No approval will be required from Chandigarh Municipal Corporation or Estate Office for putting up solar plants in existing or new buildings

ANNEXURE - 3

Sanitation Requirements

Sanitation requirements for Shops and Commercial Offices 

Sr.
No.
Sanitary Unit / Fittings For Personnel
1 Water closet One  for  every  25  persons  or  part  thereof  exceeding  15 (including employees and customers). For female personnel 1
for every 15 persons or part thereof exceeding 10.
2 Drinking Water Fountain One for every 100 person with a minimum of one on each
floor.
3 Wash Basin One for every 25 persons or part thereof.
4 Urinals Nil upto 6 persons 1 for 7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 add @ 3%;
For over 200 persons add @ 2.5%.
5 Cleaners’ Sink One per floor minimum, preferably in or adjacent to sanitary
rooms.

Note: Number of customers for the purpose of the above calculation shall be the average number of persons in the premises for a time interval of one hour during the peak period. For male-female calculation a ratio of 1: 1 may be assumed.

Sanitary Requirements for Hotels

Sr.
No.
Sanitary Unit For Residential Public staff For non residential Staff
For male For female
1 Water Closet (W.C.) One per 8 Persons omitting occupants of the attached water closet minimum of 2 if both sexes are lodged 1        for            1-15
persons
2       for           16-35
persons
3       for           36-65
persons
4      for          66-100
person
2 for 1-12 persons
4        for           13-25
persons
6        for           26-40
persons
8        for           41-57
persons
10for                 58-77
persons 12for78-100
persons
Add 1 for every 6 persons   or          part thereof.
2 Ablution Taps One in each W.C. One in each W.C. One in each W.C.
3 Urinals Nil Nil        upto           6
persons
1        for            7-20
persons
2       for           21-45
persons
3       for           40-70
persons
4      for          71-100
persons
Nil
4 Wash Basins One per 10 persons omitting each basin installed in the room / suite 1 for 15 persons
2       for           16-35
persons
3       for           36-65
persons
4      for          66-100
persons
1 for 1-12
2 for 13-25
3 for 26-40
4 for 41-57
5 Baths One per 10 persons, less occupants of room
with bath in suite
Nil Nil
6 Cleaner’s Sinks One per 30 Bed rooms (one per floor
minimum)
Nil Nil
7 Kitchen Sink One in each Kitchen One in each
Kitchen
One in each
Kitchen

Contd: For Public Rooms

Sr.
No.
Sanitary Unit For Male For Female
1 Water Closet One per 100 persons upto 400 persons; for over 400 add at the rate of one per 250 persons or part thereof. Two for 100 persons upto 200 persons;
over 200 add at the rate of one per 100
persons or part thereof.
2 Ablution Taps One in each W.C. One in each W.C.
3 Urinals One for 50 persons or part thereof. il,  upto  6  persons  1  for  7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
4 Washbasins One per WC/Urinal One per WC
5 Kitchen Sink One in each Kitchen One in each Kitchen
6 Baths (showers) One per 10 persons
7 Cleaner’s Sinks One per 30 Bed rooms (one per floor minimum)

Note: i) It may be assumed that the two-thirds of the number are males and one- third females.

ii) One water tap with drainage arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinals.

Sanitation Requirements for Educational Occupancy

Sr.
No.

Sanitary Unit Boarding Institution Other Educational Institution
For Boys For Girls For Boys For Girls
1 Water Closet One for 8 boys or part thereof One for 6 girls or part thereof ne  for  40  boys  or part thereof One     fo r25
part
girls     or thereof
2 Ablution Taps One in each
W.C.
One in     each
W.C.
One in each W.C. One    in each
W.C.
3 Urinals One per every 25 pupils or part
thereof
            One per every 20 pupils or part
thereof
 
   
 
4 Wash basins One for every 8 pupils or part thereof One for every 6 pupils or part thereof One for every 60 pupils or part thereof One for every 40
pupils or part
thereof
5 Baths One for every 8 pupils or part
thereof
One for every 6 pupils or part
thereof
 
   
 
6 Baths (showers) One for every 50 pupils or part thereof One 50
part
thereof
One for every 50 pupils or part thereof One for every 50
pupils or part
thereof
7 Cleaner’s
Sinks
One per Floor
minimum
One      per   Floor
minimum
OneperFloor
minimum
One per Floor
minimum

Contd: Nursery Schools

Sr.
No.
Sanitary Unit Requirement
1 Water Closet One for 15 boys, one for 6 girls
2 Ablution Taps One in each W.C.
3 Urinals One for 12 boys
4 Wash Basins One for every 15 pupils or part
thereof
5 Baths One bath per 40 pupils
6 Drinking Water Fountains One for every 50 pupils or part
thereof
7 Cleaner’s Sink One per Floor minimum

Note: 1. One water tap with draining arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closets and urinal.

2. For teaching staff, the schedule of sanitary units to be provided shall be the same as in case of office Buildings

Sanitation Requirements for Institutional (Medical) Occupancy- Hospital
 

Sr.No. Sanitary Unit Hospitals With indoor Patient Ward For Males & females Hospitals With outdoor Patient Wards
      For Males For Females
1 Toilet Suite (1WC+1Washbasin+
1shower)
Private persons room   upto For upto 4 patients
2 Water Closet (W.C.) One for every 8 beds or part thereof One     for     every 100 persons or part
thereof
O  ne  for  every  25 persons
or part thereof
3 Ablution taps One in each W.C. One in each W.C. One in each W.C.
4 Wash Basins Two upto 30 bed; add one
for  every  additional           30
beds; or part thereof
One for every 100 persons or part thereof One    for         every  25
persons        or          part thereof.
5 Baths with Shower One bath with shower for every  8   beds   or   part
thereof.
-- --
6 Bed pan washing
sink
One for each ward -- --
7 Cleaner’ Sinks One for each ward One          per floor
minimum
One         per            floor
minimum
8 Kitchen sinks & dish Washers (where
Kitchen is provided)
One for each ward -- --
9 Urinals One for 30 beds (male wards) One     for     every persons or part
thereof
 
10 Drinking water
fountain
One for each ward One for 500 persons or part thereof

Contd: Administrative Buildings

Sr.
No.
Sanitary Unit For Males For Females
1 Toilet Suite (1WC+1Washbasin+
1shower)
For individual doctor’s/officer’s rooms
2 Water Closet (W.C.) One for every 25 persons or part
thereof
Two      for      every         25
persons or part thereof
3 Ablution Taps. One in each W.C One in each W.C
4 Wash Basins One for every 25 persons or part
thereof
One      for      every         25
persons or part thereof
5 Baths with Shower One on each floor One on each floor
6 Cleaner’s Sink One per floor minimum One per floor minimum
7 Kitchen sinks & dish Washers (where Kitchen
is provided)
One for each floor One for each floor
8 Urinals Nil upto 6 persons 1 for 7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 persons add at the rate of 3%; for over 200 persons add at the rate of 2.5%.
--
9 Drinking water fountain One for 100 persons or part thereof  

Sanitation Requirements for Institutional (Medical) Occupancy- (staff quarters and Hostels) 

Sr. No. Sanitary Unit Doctor’s Dormitories Nurses Hostel
For Male Staff For female staff
1 Water Closet (W.C.) One for 4 persons One          for         2
persons
One          for         2
persons or part thereof
Two for 13-25
2 Ablution Taps. One in each W.C. One    in           each
W.C.
One       in         each
W.C. O
3 Wash Basins One for every 8 persons        or       part
thereof
One for every 8 persons      or     part
thereof
One for every 8 persons      or     part
thereof
4 Baths with Shower One for every 4 persons        or       part
thereof
One for every 4 persons      or     part
thereof
One for every 4 persons      or     part
thereof
5 Cleaner’s Sink One per floor
minimum
One per floor
minimum
One per floor
minimum
6 Drinking water fountain One for 100 persons or part thereof One      for         100
persons      or     part
thereof

Sanitation Requirements for Governmental and Public Business Occupancy and Offices.

Sr.
No.
Sanitary Unit For Male Personnel For Female Personnel
1 Water Closet One for 25 persons or part thereof Two for 15 persons or part
thereof
2 Ablution Taps One in each W.C. One in each W.C.
3 Urinals Nil upto 6 persons 1 for 7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 add @ 3%;
For over 200 persons add @ 2.5%.
-------
4 Wash basins One for every 25 persons or part
thereof
One for every 25 persons or
part thereof
5 Drinkingwater fountains One for every 100 persons with a minimum of one on each floor One  for  every  100  persons with a
minimum  of  one  on  each
floor
6 Cleaner’s Sinks One per floor minimum; preferably in
or adjacent to sanitary rooms.
-------
7 Executive Room / Conference Halls Toilet Suite (1 WC, 1 washbasin, optional shower for 24 hr usages) Unit could be common for Male/Female or separate depending on the number of user
of each facility

Note: One water tap with drainage arrangements shall be provided / 50 persons or part thereof in the vicinity.

Segregated sanitation facilities for Visitors in Public Buildings

Sr.
No.
Sanitary Unit For Male Personnel For Female Personnel
1 Public toilet near Railway Stations (24x7)
a) Water Closet(W.C)
b) Urinals
c) Ablution taps
a) One for 100 users
b) One unit per 300-500 users
c) One in each W.C.
a) One for 50 users
b) --
c) One in each W.C.
2 Public Toilet near market place/offices (for working hours)
a) Water Closet
b) Urinals
c) Ablution taps
a) One for 100 users
b) One unit per 200-300 users
c) One in each W.C.
a) One for 50 users
b) --
c) One in each W.C.
3 Public toilets near Public Buildings
a) Water Closet
b) Urinals
c) Ablution taps
a) One for 100 users
b) One unit per 200-300 users
c) One in each W.C.
a) One for 50 users
b) --
c) One in each W.C.

The recommended enclosure-sizes for different facilities at visitors’ toilets

Sr.
No.
Description Optimum (mm) Minimum (mm)*
1 Water Closet enclosures 900x1200 750x900
2 Urinals (divided by partition walls) 575x675 500x600

*In case of space constraint, the minimum sizes may be adopted

The recommended areas for different facilities at visitors’ toilets
 

Sr.
No.
Sanitary Unit Dwelling with individual
conveniences
Dwelling           without          individual conveniences
1 Bath Room One provided
with water tap
One for every two tenement
2 Water Closet (W.C.) One One for every two tenement
3 Sink (or Nahani) in
the Floor
One -----
4 Water Tap One One  with  drainage  arrangement  in each tenement
One  in  common  bath  rooms  and
common water closet.

Note: Where only one water closet is provided in a dwelling, the bath and water closet shall be separately accommodated.

Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.)
 

Sr. No. Sanitary Unit For Public For Staff
For Male For female For Male For female
1 Water           Closet (W.C.) One for 100
persons upto 400 persons. For over 400 persons,
add at the rate of 1 per 250 persons or part
thereof
Four for 100 persons upto 200 persons.
For over 200 persons
add at the rate of 1 per 50 persons or part
thereof
One for 15 persons.
Two for 16-35 persons
Two    for      1-
12 persons.
Four for 13-
25 persons
add     at      the rate of 1 per
6 persons or
part thereof
2 Ablution Taps. One in each W.C. One  in  each W.C. One  in  each W.C. One in each W.C.
3 Urinals One for 50 persons or part thereof ------ Nil upto 6 persons
One for 7-20 persons
Two for 21-45
persons
--------
4 Wash Basins One for every One for every One for 1-15 One for 1-

Note: i) One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.

Sanitation Requirements for Assembly Buildings (Art, Galleries, Libraries and Museums).

Sr.
No.
Sanitary Unit For Public For Staff
For Male For female For Male For female
1 Water         Closet (W.C.) ne  for  200  persons upto 400 persons.
For over 400 persons, add  at  the  rate  of  1 per 250 persons or part thereof
Four for 100 persons            upto 200
persons.
For over 200 persons,        add  at the
rate of 1 per 50 persons or part
thereof
One for 1-15 persons.
Two for 16-35 persons.
Two  for       1-
12
persons. Four for 13-
25
persons, add at
the rate of 1 per                 6
persons.
2 Ablution Taps. One in each W.C. One       in       each W.C. One in each W.C. One in each W.C.
3 Urinals One for 50 persons or part thereof ------ Nil upto 6 persons One for 7-20 persons
Two for 21-45
persons
--------
4 Wash Basins One  for  every  200 persons or part thereof. For over 400 persons, add at the rate of 1 per 250 persons or part thereof. One      for      every 200
persons or part thereof. For over 200 persons, add at
the rate of 1 per 150
persons or part
thereof
One for 1-15 persons
Two for 16-35
One  for        1-
12 persons
Two for 13-
25
persons
5 Drinking Water
Fountain
One for 100 persons or part thereof
6 Cleaner’s Sink One per floor, minimum
7 Shower/Bathing As per trade requirements

Note: It may be assumed that two thirds of the numbers are males and one third females.

Sanitation Requirements for Restaurants

Sr. No. Sanitary Unit For Public For Staff
For Male For female For Male For female
1 Water (W.C.) Closet One  per 50 seats upto 200
seats. For over 200 seats, add at the rate of 1 per 100 seats or part thereof
One per 25
seats upto 200 seats. For over 200 seats, add at the rate of 1 per 50 seats or part thereofthereof
One      for  15 persons.
2 for 16-35 persons.
3 for 36-65 persons.
4 for 66-100 persons.
Two  per  1-
12 persons.
4  for  13-25 persons.
6  for  26-40 persons.
8  for  41-57 persons.
10 for 58-77 persons.
12  for  78- 100 persons. thereof
2 Ablution Taps. One in each W.C. One  in  each W.C. One     in  each W.C. One in each W.C.
3 Urinals One for 50 persons or part thereof ------ Nil      upto  6 persons.
1   for   7-20 persons.
2 for 21-45 persons.
3 for 46-70 persons.
4 for 71-100
persons.
--------
4 Wash Basins One for every 200 persons or
part thereof
5 Kitchen Sinks &
Dish Washer
One per each Kitchen
6 Cleaner’s Sink One per floor
7 Service Sink One in the restaurant

Note: i) It may be assumed that two thirds of the numbers are males and one-third females.

ii) One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinal.

Sanitation Requirements for Factories

Sr.
No.
Sanitary Unit For Male Personnel For Female Personnel
1 Water              Closet (W.C.) 1 for 15 persons
2 for 16-35 persons
3 for 36-65 persons.
4 for 66-100 persons.
For 101 to 200 persons add at rate of 3%. From over 200 persons, add at the rate of 2.5%
2 for 1-12 persons
4 for 13-25 persons.
6 for 26-40 persons.
8 for 41-57 persons.
10 for 58-77 persons.
12 for 78-100 persons.
For 101 to 200 persons, add at the rate of 3%. From over 200 persons
add at the rate of 2%..
2 Ablution Taps. One in each W.C. One in each W.C.
3 Urinals Nil upto 6 persons 1 for 7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 persons add at the rate of 3%; for over 200
persons add at the rate of 2.5%.
----------
4 Washing Taps with draining
arrangement
One for every 25 persons or part thereof
5 Drinking Water
Fountains
One for every 100 persons with a minimum of one on each floor
6 Baths Preferably
Showers
As required for particular trade or occupation
7 Emergency shower and eye wash
fountain
One per every shop floor per 500 person

Note:

i) For many trades of a dirty or dangerous character, more extensive provisions are required

ii) One water tap with draining arrangement shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinal.

iii) Creche where provided shall be fitted with water closets (One for 10 persons or part thereof), wash basins (1 for 15 persons or part thereof) and drinking water tap with drinking arrangement for every 50 persons or part thereof.

Sanitary Requirements for Large Stations and Airports.

Sr.
No.
Place W.C. for Males W.C. for Females Urinals       for         Males only
1 Junction Stations, Intermediate Stations and Substations 3 for first 1000 persons, add 1 for subsequent 1000 persons or part thereof. 8 for first 1000 persons, add 1 for every additional 1000 persons or part thereof. 4      for       every        1000 person,
add 1 for every
additional                    1000
persons
or part thereof.
2 Terminal Stations and Bus Terminals for first 1000 persons and 1 for
every additional 1000 persons or part thereof.
10 for every 1000 person and 1 for every additional 1000 persons or part
thereof.
6      for       every        1000 person
and         1    for         every
additional                    1000
persons
or part thereof.
3 Domestic Airports 2* 16 1  per  40  persons  or part thereof.
  Minimum. 5 30  
  For 200 persons 9 40  
  For 400 persons 12 52  
  For 600 persons 16 58  
  For 800 persons 18    
  For 1000 persons      
4 International Airports 6 20 1  per  40  persons  or part thereof.
  For 200 persons 12 40  
  For 600 persons 18 58  
  For 1000 persons      

Note: i) Provision for wash basins, baths including shower stalls, shall be in accordance with part IX Section 2-Drainage and Sanitation of National Building Code of India.

* At least one Indian style water closet shall be provided in each toilet. Assume 60 % males and 40 % females in any area.

* At least 50 % of female WCs may be Indian pan and 50% EWC.

General Standards/Guidelines for Public Toilets in Public Area.

Public Toilet On roads and for open areas: At every 1 km, including in parks, plaza, open air theatre, Swimming area, car parks, and fuel stations. Toilets shall be disabled-friendly and in 50-
50 ratio (M/F). Provision may be made as for Public Rooms (Table 4.10 Contd)
Signage Signboards on main streets shall give directions and mention the distance to reach the nearest public convenience. Toilets shall have multi-lingual signage for the convenience
of visitors. Helpline number shall be pasted on all toilets for complaints/queries.
Modes And use or free. In pay and use toilets entry is allowed on payment to the attendant or by
inserting coin and user gets 15 minutes.
Maintenance/ Cleaning The toilet should have both men and women attendants. Alternatively automatic cleaning cycle  covering  flush,  toilet  bowl,  seat,  hand  wash  basin,  disinfecting  of  floor  and complete drying after each use can be adopted, which takes 40 seconds.
Public toilet shall be open 24 hours.