Electro Mechanical -3
1 | 2 | 3 | 4 | 5 | |
Thermal Insulation | |||||
268 | ELEC-5.6.26 | Supply &Fixing of Duct Thermal Insulation applied outside of the duct work with All. backed Closed cell nitrile/ Cross linked foam duly fixed with adhesive and tapes. | |||
13 mm Thick | sqm | 580 | |||
Accoustic Insulation | |||||
269 | ELEC-5.6.27 | Supply & Fixing of Duct Accoustic Insulation applied inside of the duct work with All. backed Open cell nitrile duly fixed with adhesive and tapes | |||
a | 10/15 mm Thick | sqm | 900 | ||
270 | ELEC-5.6.28 | Supply, Installation, Testing and commissioning of extruded Aluminum powder coated grills/ diffusers for supply with removable core type with collar damper | sqm | 8500 | |
271 | ELEC-5.6.29 | Supply, Installation, Testing and commissioning of extruded Aluminum powder coated grills/ diffusers for retrun with removable core type without collar damper | sqm | 6200 | |
272 | ELEC-5.6.30 | Supply , Erection and Testing of GI Opposed blade Volume control dampers made out of 18G frame and 20G blades | sqm | 5400 | |
273 | ELEC-5.6.31 | Supply , Erection of Fresh air louver with extruded aluminium grill with SS wire mesh and GI volume control damper with 20 micron filters | sqm | 4300 | |
274 | ELEC-5.6.32 | Supply and Installation of Underdeck Insulation with 50 mm thk EPS, 48 Kg/Cum density, factory laminated faced alumimun foil coreved with GI cross wiring. | sqm | 650 | |
275 | ELEC-5.6.33 | Supply and Installation of GI Fusible link Fire dampers 500 mm long with sleeve as per UL 555 Standard,Minimum width of damper shall be 225 mm. | sqm | 6500 | |
276 | ELEC-5.6.34 | Supply and Installation of GI backdraft dampers as per UL 555 Standard, | sqm | 5400 | |
277 | ELEC-5.6.35 | Supply, installation and testing of Canvas connection for the Treated Fresh Air units to the duct | each | 2200 | |
5.7 | EVAPORATIVE AIR COOLING SYSTEM | ||||
278 | ELEC-5.7.1 | Supply of single phase evaporative air cooling unit with a capacity of 9000 CFM consisting cabinet and water tank made of polypropylenematerial, blower water pump of 40W, single phase 1.20 KW motor axial type fan with variable speed, 20 micron filteration, noise levelless than 78 dBA with auto cleaning,humidity control and water lack protection etccomplete. Makes: Cool Breeze / Breeze Air | 1 No | 105000 | |
279 | ELEC-5.7.2 | Supply of Three phase evaporative air cooling unit with a capacity of 12000 - 15000 CFM consisting cabinet and water tank made of polypropylene material, blower water pump of 40W, Three phase 3.0 KW motor axial type fan with 2 speed, 20 micron filteration, noise level less than 78 dBA with auto cleaning and water lack protection etc complete. Makes: Cool Breeze /Breeze Air |
1 No | 180000 | |
280 | ELEC-5.7.3 | Supply and fixing of 13mm thick Nitrile insulation for out door unit. | 1 sft | 55 | |
281 | ELEC-5.7.4 | Supply and fixing of 50mm thick glasswool of 24 kg density with alluminium foil insulation for indoor duct. | 1 sft | 58 | |
282 | ELEC-5.7.5 | Supply and fixing of angular iron frame with 2 coats of zincromat red oxide for installation of air cooling unit | 1 No | 5000 | |
283 | ELEC-5.7.6 | Installation and commissioning charges for air cooling unit | 1 No | 3600 | |
5.8 | STABILIZERS | ||||
284 | ELEC-5.8.1 | Supplly of ………... Stabilizer. Makes: V- Guard / Real Guard / Uni Stab / ITL. | |||
a | 0.5 KVA | 1 No | 820 | ||
b | 1.0 KVA | 1 No | 1450 | ||
c | 3.0 KVA | 1 No | 2000 | ||
d | 4.0 KVA | 1 No | 2700 | ||
e | 5.0 KVA | 1 No | 3300 | ||
285 | ELEC-5.8.2 | Supplly of ………... Stabilizer. Makes: Keeline / Soft Line | |||
a | 0.5 KVA | 1 No | 675 | ||
b | 1.0 KVA | 1 No | 1300 | ||
c | 3.0 KVA | 1 No | 1700 | ||
d | 4.0 KVA | 1 No | 2500 | ||
e | 5.0 KVA | 1 No | 3100 | ||
5.9 | REPAIRING OF FANS, COOLERS, PUMPS, MOTORS, FRIDGES AND AIRCONDITIONERS | ||||
286 | ELEC-5.9.1 | Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. (New model ceiling fan) | |||
a | 900/1200 mm sweep | 1 No | 325 | ||
b | 1400 mm sweep | 1 No | 390 | ||
287 | ELEC-5.9.2 | Charges for oiling, greasing, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required | 1 No | 150 | |
288 | ELEC-5.9.3 | Providing and Replacement of ball bearing of ceiling/ exhaust fan as required. (NBC/ SKF) | 1 No | 175 | |
289 | ELEC-5.9.4 | Providing and Replacement of Gun metal bush of ceiling/ exhaust/cooler fan/ as required | 1 No | 150 | |
290 | ELEC-5.9.5 | Servicing and overhauling of 20" sweep desert cooler including oiling, greasing, painting of tank from inside with rubber paint after properly desmantling each assembly and refixing the same as required. | 1 No | 250 | |
291 | ELEC-5.9.6 | Painting of desert cooler with two coats of rubber paint inside of water tank and two coat of synthetic enamelled paint on both side of cooler body, fan body, grills etc.after cleaning with sand paper, complete in all respect as required | 1 No | 450 | |
292 | ELEC-5.9.7 | Replacement of cooler pads (heavy) set of 3 no. of size 25" x 27" | 1 No | 150 | |
293 | ELEC-5.9.8 | Supply and fixing of Brass float valve of weighing approx. 250 gm, 8" long rod,PVC ball of 4" dia. For desert coler as required. | 1 No | 200 | |
294 | ELEC-5.9.9 | Supply and fixing of adjustable M.S.grill 20/22 gauge of size approx. 24" x 26" including painting etc. as required | 1 No | 360 | |
295 | ELEC-5.9.10 | Spray painting of ceiling fan of size 900/1200/ 1400 mm with two coats of white/ brown enamelled paint after cleaning with sand paper. Filling etc. as required. | 1 No | 175 | |
296 | ELEC-5.9.11 | Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. |
|||
a | 300/ 380 mm sweep | 1 No | 550 | ||
b | 450 mm sweep | 1 No | 650 | ||
c | 600 mm sweep | 1 No | 1100 | ||
297 | ELEC-5.9.12 | Rewinding of 400 mm table fan/pedestal fan motor including all necessary material,The motor is to be wound taking no. of coils,turnsand pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. | 1 No | 350 | |
298 | ELEC-5.9.13 | Rewinding of single phase motor of 1400 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. | 1 No | ||
a | 0.5 H.P. To 1.00 H.P. | 1 No | 700 | ||
b | 2.0 H.P | 1 No | 1150 | ||
299 | ELEC-5.9.14 | Rewinding of three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. | |||
a | 3.0 H.P. | 1 No | 1700 | ||
b | 5.0 H.P. | 1 No | 2400 | ||
c | 7.5 H.P | 1 No | 2600 | ||
d | 10.0 H.P | 1 No | 3500 | ||
e | 12.5 H.P | 1 No | 3700 | ||
f | 15.0 H.P | 1 No | 4500 | ||
300 | ELEC-5.9.15 | Supply and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capallary and strainer/ filter. |
|||
a | 1.0 TR Window/ Split A.C | 1 No | 1900 | ||
b | 1.5 TR Window/ Split A.C | 1 No | 2100 | ||
c | 2.0 TR Window/ Split A.C | 1 No | 2500 | ||
d | 25/50 / 40/80 Ltr. Water cooler | 1 No | 2000 | ||
e | 60/120 Ltr. Water cooler | 1 No | 2300 | ||
f | 150/150 Ltr. Water cooler | 1 No | 2800 | ||
g | 165 Ltr Refrigerator | 1 No | 1250 | ||
h | 200/210 Ltr Refrigerator | 1 No | 1800 | ||
i | 286/310 Ltr Refrigerator | 1 No | 2100 | ||
301 | ELEC-5.9.16 | Replacement of defective compressor by company repaired compressor of fridge./water cooler including testing etc. as required. (Carrier/ Kirlosker/ Techam-Shah/ Shriram/ Voltas) | |||
a | 25/50 / 40/80 Ltr. Water cooler | 1 No | 6000 | ||
b | 60/120 Ltr. Water cooler | 1 No | 7600 | ||
c | 150/150 Ltr. Water cooler | 1 No | 9000 | ||
d | 165 Ltr Refrigerator (Carrier/ Kirlosker/ Techam-Shah/ Shriram/ Voltas/ BPL/ Zenith/ Kelvinator) | 1 No | 3100 | ||
e | 200/210 Ltr Refrigerator (Carrier/ Kirlosker/ Techam-Shah/ Shriram/ Voltas/ BPL/ Zenith/ Kelvinator) | 1 No | 3800 | ||
f | 286/310 Ltr Refrigerator (Carrier/ Kirlosker/ Techam-Shah/ Shriram/ Voltas/ BPL/ Zenith/ Kelvinator) | 1 No | 4300 | ||
302 | ELEC-5.9.17 | Supply of ……… brandnew Rotary type sealed compressor for Air conditioner Makes: DAIKIN/LG/Carrier/Kirloskar/Techam-shah | |||
a | 1.0/1.5 TR | 1 No | 9500 | ||
b | 2 TR | 1 No | 10450 | ||
303 | ELEC-5.9.18 | Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required | |||
a | 1.0 TR A.C. | 1 No | 3565 | ||
b | 1.5 TR A.C. | 1 No | 4025 | ||
c | 2.0 TR A.C. | 1 No | 4485 | ||
d | 25/50 / 40/80 Ltr. Water cooler | 1 No | 2400 | ||
e | 60/120 Ltr. Water cooler | 1 No | 3500 | ||
f | 150/150 Ltr. Water cooler | 1 No | 3500 | ||
g | 165 Ltr Refrigerator | 1 No | 1100 | ||
h | 200/210 Ltr Refrigerator | 1 No | 1200 | ||
i | 286/310 Ltr Refrigerator | 1 No | 1550 | ||
304 | ELEC-5.9.19 | Replacement of overload protection of A.C./ Water cooler as required | 1 No | 500 | |
305 | ELEC-5.9.20 | Replacement of thermostat of A.C./ Water cooler/fridge as required. | 1 No | 450 | |
306 | ELEC-5.9.21 | Replacement of starting relay of A.C/water cooler/fridge compressor as required | 1 No | 490 | |
307 | ELEC-5.9.22 | Spray painting of complete fridge (inside and outside ) of 165/ 200/286/310 Ltr. Capacity | 1 No | 1600 | |
308 | ELEC-5.9.23 | Supply and fixing of 230V/ 275V, 50Hz rating ………. | |||
Starting capacitor | |||||
a | 20-60 micro farad | 1 No | 200 | ||
b | 80-150 micro farad | 1 No | 400 | ||
Running capacitor | 1 No | ||||
a | 2.5/3.15/4.0/6.0 micro farad | 1 No | 75 | ||
b | 8.0 micro farad | 1 No | 110 | ||
c | 10.0 micro farad | 1 No | 150 | ||
d | 15.0 to 36.0 micro farad | 1 No | 350 | ||
309 | ELEC-5.9.24 | Supply, Fabrication of 1set MS bracket suitable for fixing out door unit of split AC unit. | 1 Set | 1200 | |
310 | ELEC-5.9.25 | Providing 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for split/Casseete Air- Conditioner including foaming etc., complete. Make: Copper:Totaline /Nippon /Mandev. Nitrile Insulation: Kflex/ Totaline /Armaflex |
|||
a | 1/2" x 1/4" | 1 Mtr | 810 | ||
b | 5/8" x 1/4" | 1 Mtr | 890 | ||
c | 3/4" x 3/8" | 1 Mtr | 975 | ||
d | 7/8" x 1/2" | 1 Mtr | 1100 | ||
e | 1 1/8" x 5/8" | 1 Mtr | 1350 | ||
311 | ELEC-5.9.26 | Multi speed Fan Motor suitable for 1.0 / 1.5 / 2.0 Ton Window A.C.Unit Makes : Crompton / AU. |
1 No | 1425 | |
312 | ELEC-5.9.27 | Air filter suitable for 1.50 Ton Window A.C.Unit P.V.C. / NYLON. | 1 No | 250 | |
313 | ELEC-5.9.28 | Air filter suitable for 1.50 Ton Split A.C.Unit P.V.C. / NYLON. | 1 No | 430 | |
314 | ELEC-5.9.29 | Fan blade for 1.0 / 1.5 Ton A.C.Machine. | 1 No | 500 | |
315 | ELEC-5.9.30 | Installation of Split Air Conditioners. | 1 No | 1600 | |
316 | ELEC-5.9.31 | Removing of existing Split Air Conditioners without damaging to copper pipe. | 1 No | 600 | |
317 | ELEC-5.9.32 | Installation of Cassette type Split Air Conditioners. | 1 No | 4000 | |
318 | ELEC-5.9.33 | Installation of Tower type Split Air Conditioners. | 1 No | 3000 | |
319 | ELEC-5.9.34 | Supply, Fabrication of 1set MS bracket suitable for fixing out door unit of 3.5 /4.50 TR Casseete AC unit. | 1 Set | 1700 | |
SECTION 6 | |||||
6.1 | SWAGED / OCTAGONAL POLES AND GARDEN POSTS | ||||
320 | ELEC-6.1.1 | Fabrication, supply and transportation of all sizes swaged poles up to site confirming to IS 2713 / 1980 specifications. The pole should be painted with primary coat of red oxide and black bituminous paint up to ground level with base plate, including cost of all materials etc., complete.(Rate per K. G) | 1 Kg | 67 | |
321 | ELEC-6.1.2 | Fabrication and Supply of M.S. Poles for garden posts with 'B' class 60.25mm outer dia with base plate and suitable pole cap including cost and conveyance of all material including fixing of luminaire and labour charges etc., complete. (Rate per K. G) | 1 Kg | 61 | |
322 | ELEC-6.1.3 | Supply of different sizes of M. S. Pipe brackets (Rate per K.G) | 1 Kg | 61 | |
OCTOGONAL POLEs | |||||
323 | ELEC-6.1.4 | Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with HInged door opening arrangement, including the supply of suitable boards with bakelite sheet as per IS specification suitable to withstand the wind speed of 180 KMPH for 7.5 Mtrs height Pole having dimensions Bottom 130 mm,. Top 70mm with 3mm thick, base plate 220 x 220 x 12mm and 4 Nos of M20 x 700 long 'J' bolts along with template. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 11760 | |
324 | ELEC-6.1.5 | Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with Hinged door opening arrangement, including the supply of suitable boards with bakelite sheet as per IS specification suitable to withstand the wind speed of 180 KMPH for 9 Mtrs height Pole having dimensions Bottom 155 mm,. Top 70mm with 3mm thick, base plate 260 x 260 x 16mm and 4 Nos of M24 x 750 long 'J' bolts along with template. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 17000 | |
325 | ELEC-6.1.6 | Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with HInged door opening arrangement, including the supply of suitable boards with bakelite sheet as per IS specification suitable to withstand the wind speed of 180 KMPH for 10 Mtrs height Pole having dimensions Bottom 175 mm,. Top 70mm with 3mm thick, base plate 275 x 275 x16mm and 4 Nos of M24 x 750 long 'J' bolts along with template. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 18690 | |
326 | ELEC-6.1.7 | Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangement, including the supply of suitable boards with bakelite sheet as per IS specification suitable to withstand the wind speed of 180 KMPH for 12 mtrs height Pole having dimensions Bottom 240mm, Top 100mm with 4mm thick, base plate 320 x320 x20mm and 4 Nos of M24 x 850 long 'J' bolts along with template. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 27000 | |
DECORATIVE DRAGON TYPE BRACKET WITH POLE | |||||
327 | ELEC-6.1.8 | Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangement, including the supply of suitableboards with bakelite sheet and MCB's as per IS specification suitable to withstand the wind speed of 180KMPH for 9 Mtrs Mounting height Pole having dimensions Bttom 185 mm,. Top 70mm with 3mm thick, base plate 275 x 275 x 20mm and 4 Nos of M24 x 1000 long 'J' bolts along with templates. Including Supply of1.5M Dragon typedecorative ................... Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
|||
a | galvanised double arm with PU Painted bracket. | 1 No | 26600 | ||
b | galvanised Single arm with PU Painted bracket. | 1 No | 22800 | ||
c | Double arm GalvanizeFinished bracket | 1 No | 22500 | ||
d | Single arm GalvanizeFinished bracket | 1 No | 20400 | ||
328 | ELEC-6.1.9 | Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangement, including the supply of suitable boards with bakelite sheet and MCB's as per IS specification suitable to withstand the wind speed of 180 KMPH for 9 Mtrs Mounting height Pole having dimensions Bottom 185 mm,. Top 70mm with 3mm thick, base plate 275 x 275 x 20mm and 4 Nos of M24 x |
1 No | DELETED | |
1000long 'J' bolts along with templates. Including Supply of 1.5M Dragon type decorative Makes : Bajaj / Valmont /Transrail/Utkarsh/ Skipper/ /United |
|||||
329 | ELEC-6.1.10 | Fabrication, Transportation and supply of hot-dip PU Paint finish Curved Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangement, including the supply of suitable boards with bakelite sheet and MCB's as per IS specification suitable to withstand the wind speed of 180 KMPH for 9 Mtrs Mounting height Curved Pole having dimensions Bottom 180 mm,. Top 85mm with 3mm thick, base plate 400 x 400 x 20mm and 4 Nos of M24 x 750 long 'J' bolts along with templates. Including Supply of 0.2M long Single arm bracket. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
|||
a | Galvanized | 1 No | 22300 | ||
b | Galvanized PU paint finshed | 1 No | 30200 | ||
POLE BRACKETS | |||||
330 | ELEC-6.1.11 | Fabrication, Transportation and supply of 1.0 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 1300 | |
331 | ELEC-6.1.12 | Fabrication, Transportation and supply of 1.50 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 1720 | |
332 | ELEC-6.1.13 | Fabrication, Transportation and supply of 1 Mtr length Double Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 1610 | |
333 | ELEC-6.1.14 | Fabrication, Transportation and supply of 1.50 Mtr length Double Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 2900 | |
334 | ELEC-6.1.15 | Fabrication, Transportation and supply of 1.5 Mtr Length Single Arm suitable size decorative galvanized Bracket with PU paint colour finish etc complete. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 4800 | |
335 | ELEC-6.1.16 | Fabrication, Transportation and supply of 1.5 Mtr Length Double Arm suitable size decorative galvanized Bracket with PU paint colour finish etc complete. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 9100 | |
336 | ELEC-6.1.17 | Fabrication, Transportation and supply of of 1.5mtrs sword type or any decorative double arm bracket with dooms either sides complete with all accessories with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 5300 | |
337 | ELEC-6.1.18 | Fabrication, Transportation and supply of of 1.5mtrs sword type or any decorative Single arm bracket with dooms either sides complete with all accessories with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 4100 | |
338 | ELEC-6.1.19 | Fabrication, Transportation and supply of of 1.0mtrs sword type or any decorative double arm bracket with dooms either sides complete with all accessories with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 4300 | |
339 | ELEC-6.1.20 | Fabrication, Transportation and supply of of 1.0 mtrs sword type or any decorative Single arm bracket with dooms either sides complete with all accessories with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 3600 | |
HIGH MAST POLES | |||||
340 | ELEC-6.1.21 | Fabrication, transportation and supply of 12 Mtrs Polygon High Mast with single section of 3mm thick of Bottom 360mm and Top 150mm dia with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate, having a base plate of size 520mm dia 16mm thick with its accessories. Mast shall be in single section for 12 Mtrs and 2 sections for 16 and 20 Mtrs. Mast shall be hot dip galvanized and suiatble for wind velocity of 180 KMPH as per IS 875 part 3 including head frame, 2 point suspension system with steel rope 6mm dia (7/19) construction double drum winch / power tool operating speed of 900 RPM, and necessary cable trailer connections and single speed motor with M24 x 800 mm foundation bolts of required quantity, suitable for 6 luminaires with GLS type aviation twin lamp. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 105000 | |
341 | ELEC-6.1.22 | Fabrication, transportation and supply of 16 Mtrs Polygon High Mast with two sections of Bottom 4mm thick and Top section with 3mm thick with GLS type aviation lamp of Bottom 360mm and Top 150mm dia with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate, having a base plate of size 560mm dia 25mm thick with its accessories. Mast shall be in single section for 12 Mtrs and 2 sections for 16 and 20 Mtrs. Mast shall be hot dip galvanized and suiatble for wind velocity of 180 KMPH as per IS 875 part 3 including head frame, 2 point suspension system with steel rope 6mm dia (7/19) construction double drum winch / power tool operating speed of 900 RPM, and necessary cable trailer connections and single speed motor with M24 x 800 mm foundation bolts of required quantity with GLS type aviation twin lamp. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 138000 | |
342 | ELEC-6.1.23 | Fabrication, transportation and supply of 20 Mtrs Polygon High Mast with two sections of Bottom 4mm thick and Top section with 3mm thick of Bottom 460mm and Top 150mm dia with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate, having a base plate of size 670mm dia 25mm thick with its accessories. Mast shall be in single section for 12 Mtrs and 2 sections for 16 and 20 Mtrs. Mast shall be hot dip galvanized and suiatble for wind velocity of 180 KMPH as per IS 875 part 3 including head frame, 2 point suspension system with steel rope 6mm dia (7/19) construction double drum winch / power tool operating speed of 900 RPM, and necessary cable trailer connections and single speed motor with M30 x 750 mm foundation bolts of required quantity with GLS type aviation twin lamp. Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/ Skipper |
1 No | 178500 | |
FEEDER PILLAR BOXES | |||||
343 | ELEC-6.1.24 | Supply and fixing of suitable out door type feeder piller box made with 14 SWG CRCA sheet after 7 tank process including S & F of Legrand / Schnieder / L&T make 40-63A FP MCB, 6 Nos SP MCB's, din chanel, bus bars, 6 Sqmm 3 core copper cable for internal wiring, contactor, connectors and provision for energy meter etc., complete for finished item of work. | 1 No | 18300 | |
344 | ELEC-6.1.25 | Supply and fixing of suitable out door type feeder piller box made with 14 SWG CRCA sheet after 7 tank process including S & F of Legrand / Schnieder / L&T make 40-63A FP MCB, 9 Nos SP MCB's,din chanel, bus bars, 6 Sqmm 3 core copper cable for internal wiring , contactor, connectors and provision for energy meter etc., complete for finished item of work. | 1 No | 18900 | |
ERRECTION- HIGH MAST POLES | |||||
345 | ELEC-6.1.26 | Earth work exacavation with a approximate quantity of 4.0 Cum for errection of 12 Mtrs high mast and refilling with a quantity of 0.53 Cum of PCC 1:4:8, 1.50 Cum M 20 grade concrete and (80 Kgs) reinforced steel of 12mm / 10mm / 8mm, Soil bearing capacity of 10 T/Sqm, Anchor plate with cost and conveyance of all above materials including labour charges for errection of High Mast and Carraige etc complete. |
1 No | 28400 | |
346 | ELEC-6.1.27 | Earth work exacavation with a approximate quantity of 6.0 Cum for errection of 16 Mtrs high mast and refilling with a quantity of 0.65 Cum of PCC 1:4:8, 2.60 Cum M 20 grade concrete and (110 Kgs) reinforced steel of 12mm / 10mm / 8mm, Soil bearing capacity of 10 T/Sqm, Anchor plate with cost and conveyance of all above materials including labour charges for errection of High Mast and Carraige etc complete. |
1 No | 35500 | |
347 | ELEC-6.1.28 | Earth work exacavation with a approximate quantity of 7.0 Cum for errection of 20 Mtrs high mast and refilling with a quantity of 0.75 Cum of PCC 1:4:8, 3.60 Cum M20 grade concrete and (140 Kgs) reinforced steel of 12mm / 10mm / 8mm, Soil bearing capacity of 10 T/Sqm, Anchor plate with cost and conveyance of all above materials including labour charges for errection of High Mast and Carraige etc complete. |
1 No | 45600 | |
348 | ELEC-6.1.29 | Supply of ……. Sizes thermo plastic cable junction boxes with IP66/67 weather proof, for outdoor installation with konckouts for cable entry including terminals etc., complete (sizes in mm) Make : Hensel/Sadhrish | |||
a | 155 X 210 X 92 | 1 No | 1650 | ||
b | 205 X 255 X112 | 1 No | 2400 | ||
c | 225 X 295 X 122 | 1 No | 8450 | ||
d | 255 X 600 X 170 | 1 No | 9300 | ||
FOUNDATION AND ERRECTION CHARGES OF POLES | |||||
349 | ELEC-6.1.30 | Erection charges for 7.50 Mts long Octagonal pole on bridge kerb portion with 4 Nos, 8" Anchor bolts with chemical treatment with suitable "J" type bolts etc duly drilling holes to RCC slab with V.C.C. M.15 concrete for suitable base concreting with necessary steel reinforcement work and curing for 7 days etc. including cost and conveyance of all material and all labour charges etc.complete as directed by the department officers. | 1 Job | 4200 | |
350 | ELEC-6.1.31 | Foundation and erection charges with special T&P, for 7.50 Mtrs long Octagonal /Conical pole duly erecting on base plate duly providing 4 Nos foundation bolts with nuts with providing of 0.45Mtr x 0.45Mtrs x1.20 Mtr size M20 cc work vibrated concreting mixing with necessary steel (10kgs) reinforcement and curing for 7 days as directed by the field engineers during execution including excavation of Earth/BT all labour charges and cost and conveyance of materials etc.complete. | 1 Job | 4900 | |
351 | ELEC-6.1.32 | Foundation and erection charges with special T&P, for 9.00Mtrs / 10Mtrs long Octagonal / Conical pole duly erecting on base plate duly providing 4 Nos foundation bolts with nuts with providing of 0.60Mtr x 0.60Mtrs x 1.40 Mtr size M20 cc work vibrated concreting mixing with necessary steel (15kgs) reinforcement and curing for 7 days as directed by the field engineers during execution including excavation of Earth/BT all labour charges and cost and conveyance of materials etc.complete. |
1 Job | 6600 | |
352 | ELEC-6.1.33 | Foundation and erection charges with special T&P, for 12Mtrs long Octagonal /Conical pole duly erecting on base plate duly providing 4 Nos foundation bolts with nuts with providing of 0.67Mtr x 0.67Mtrs x 1.50 Mtr size M20 cc work vibrated concreting mixing withnecessary steel (20kgs) reinforcement and curing for 7 days as directed by the field engineers during execution including excavation of Earth/BT all labour charges and cost and conveyance of materials etc.complete. | 1 Job | 8100 | |
GRP POLES | |||||
353 | ELEC-6.1.34 | Supply and transportation of following glass reinforced polymer (GRP) composite type Conical pole with single arm bracket of length 1Mtr and internal junction box including labour charges etc., complete. Makes: Bajaj / Kemrock / Valmont/Sumip/Helipole |
|||
a | …do…. 3.00 Mtrs height, Bottom dia 143mm, Top 76mm, AV thickness 6mm and to withstand maximum wind velocity 180Km/Hr | 1 No | 8500 | ||
b | …do…. 4.00 Mtrs height, Bottom dia 143mm, Top 76mm, AV thickness 6mm and to withstand maximum wind velocity 180Km/Hr | 1 No | 10800 | ||
c | …do…. 6.00 Mtrs height, Bottom dia 143mm, Top 76mm, AV thickness 6mm and to withstand maximum wind velocity 180Km/Hr | 1 No | 13500 | ||
d | …do…. 8.00 Mtrs height, Bottom dia 193mm, Top 76mm, AV thickness 6mm and to withstand maximum wind velocity 180Km/Hr | 1 No | 17400 | ||
e | …do…. 9.00 Mtrs height, Bottom dia 210mm, Top 76mm, AV thickness 6mm and to withstand maximum wind velocity 180Km/Hr | 1 No | 19000 | ||
f | …do…. 10.00 Mtrs height, Bottom dia 227mm, Top 76mm, AV thickness 6mm and to withstand maximum wind velocity 180Km/Hr | 1 No | 27500 | ||
354 | ELEC-6.1.35 | Supply and transportation of base bracket suitable for glass reinforced polymer (GRP) composite type pole including labour charges etc., complete. Makes: Bajaj / Kemrock / Valmont/Sumip / Helipole |
|||
a | …do…. For 3.00 Mtrs Pole | 1 No | 1550 | ||
b | …do…. For 4.00 Mtrs Pole | 1 No | 1550 | ||
c | …do…. For 6.00 Mtrs Pole | 1 No | 1850 | ||
d | …do…. For 8.00 Mtrs Pole | 1 No | 2150 | ||
e | …do…. For 9.00 Mtrs Pole | 1 No | 4100 | ||
f | …do…. For 10.00 Mtrs Pole | 1 No | 5100 | ||
6.2 | LT PANEL AND ACCESSORIES | ||||
355 | ELEC-6.2.1 | Supply Installation Testing and commissioning of free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness,separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be abricated from CPRI approved fabricator). | 1 sqm | 4250 | |
356 | ELEC-6.2.2 | Supply and fixing of…………….. bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves | |||
a | Electrolytic grade aluminium bus bar | kg | 375 | ||
b | Electrolytic grade copper bus bar | kg | 750 | ||
357 | ELEC-6.2.3 | Supply and Fixing of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec |
|||
a | Analog type ( 96 mm x 96 mm ) | 1 No | 850 | ||
b | Digital type | 1 No | 1900 | ||
358 | ELEC-6.2.4 | Supply and Fixing of CT operated direct reading type Ammeter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Make: Conzerve/Elmeasure/ Meco/HPL/L&T/Schneider/AE/Socomec | |||
Analog type ( 96 mm x 96 mm ) | |||||
a | Below 500 A | 1 No | 850 | ||
b | Above 500A | 1 No | 850 | ||
Digital type | |||||
c | Below 500 A | 1 No | 1900 | ||
d | Above 500 A | 1 No | 1900 | ||
359 | ELEC-6.2.5 | Supply and Fixing of Current Transformer , with all necessary support in existing panel including connection etc. as required Make: Kappa/L&T/Seimens/C&S/Schneider | |||
a | up to 150 / 5 Ratio , 5 VA , class 1 accuracy | 1 No | 475 | ||
b | from 200 / 5 to 400/5 Ratio , 10 VA , class 1 accuracy | 1 No | 700 | ||
c | from 500 / 5 to 1600/5 Ratio , 15 VA , class 1 accuracy | 1 No | 950 | ||
d | from 2000 / 5 to 3200 /5 Ratio , 15 VA, class 1 accuracy | 1 No | 1500 | ||
360 | ELEC-6.2.6 | Supply and Fixing of selector switch for voltmeter (4 position ) including making connection etc. as required Make: L&T /C&S/SALZER/HPL | 1 No | 340 | |
361 | ELEC-6.2.7 | Supply and Fixing of CT linked selector switch of 10 A for Ampere meter (4position ) including making connection etc. as requiredMake: L&T /C&S/SALZER/HPL |
1 No | 375 | |
362 | ELEC-6.2.8 | Supply and fixing of single phase Electronic energy Meter,… AC,50 HZ as per IS13010 up to 40A range with 200% over load capacity complete with connections etc., complete on the existing board. Makes: CONZERVE / ELMEASURE / MECO / HPL / HAVELLS/L&T. |
|||
a | Single Phase | 1 No | 1000 | ||
b | Three Phase | 1 No | 2800 | ||
363 | ELEC-6.2.9 | Supply and Fixing of 240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required | |||
a | Red/yellow/Green colour | 1 No | 120 | ||
b | Blue colour | 1 No | 200 | ||
364 | ELEC-6.2.10 | Supply and Fixing of Tap-off boxes suitable for following size of approved design | |||
a | up to 95 sq. mm.( 3.5/4 core ) | 1 No | 400 | ||
b | from 120 sq. mm. to 185 sq. mm.( 3.5/4 core ) | 1 No | 700 | ||
365 | ELEC-6.2.11 | Supply and Fixing of energy analyser (multy function energy meter) with LCD/LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect. |
1 No | 10500 | |
366 | ELEC-6.2.12 | Supply Installation Testing and commissioning of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required.Makes: L&T/Seimens/Epcos/Schneider/Havells |
|||
a | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) | 1 KVAR | 200 | ||
b | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) | 1 KVAR | 300 | ||
367 | ELEC-6.2.13 | Supply Installation Testing and commissioning of microprocessor based intelligent power factor correction relay having sensitivity up to 50 milli Amp secondary current and following way, self analysing auto c/k setting according to targeted power factor setting, the relay shall have minimum three digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release etc. as required Makes: L&T/Seimens/Epcos /Schneider/ ABB/Neptune | |||
6 to 14 stage - sensitivity upto 50 milli Amp | 1 No | 18500 | |||
368 | ELEC-6.2.14 | Supply and Fixing of Cam operated rotary switches on existing panel with 2 way and off position makes: L&T (SALZER)/ABB/Schneider/Seimens/C&S/HPL | |||
one pole | |||||
a | 16 A | 1 No | 350 | ||
b | 32 A | 1 No | 450 | ||
c | 63 A | 1 No | 650 | ||
Two pole | |||||
d | 16 A | 1 No | 400 | ||
e | 32 A | 1 No | 530 | ||
f | 63 A | 1 No | 875 | ||
Three pole | |||||
g | 16 A | 1 No | 500 | ||
h | 32 A | 1 No | 700 | ||
i | 63 A | 1 No | 1250 | ||
Four pole | |||||
j | 16 A | 1 No | 500 | ||
k | 32 A | 1 No | 750 | ||
l | 63 A | 1 No | 1400 | ||
369 | ELEC-6.2.15 | Supply and Fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells | |||
3 pole AC3 Rating contactors | |||||
a | Up to 12 Amp | 1 No | 800 | ||
b | 13 to 32 Amp | 1 No | 1325 | ||
c | 35 to 40 Amp | 1 No | 1600 | ||
d | 41 to 50 Amp | 1 No | 3500 | ||
4 pole AC 1 Rating contactors | |||||
e | Up to 25 Amp | 1 No | 1000 | ||
f | 26 to 32 Amp | 1 No | 1200 | ||
g | 33 to 45 Amp | 1 No | 2000 | ||
h | 46 to 60 Amp | 1 No | 4200 | ||
370 | ELEC-6.2.16 | Supply and Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick dischargedamping resistors/ reactors to limit the inrush current ,conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type ncluding making onnections, testing etc. as required. suitable for following capacity capacitor bank Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells |
|||
a | Up to 6 KVAR | 1 No | 1600 | ||
b | 7 to 10 KVAR | 1 No | 1800 | ||
c | 11 to 20 KVAR | 1 No | 2700 | ||
d | 21 to 25 KVAR | 1 No | 3600 | ||
e | 30 KVAR | 1 No | 5200 | ||
f | 40 KVAR | 1 No | 8300 | ||
g | 50 KVAR | 1 No | 9600 | ||
371 | ELEC-6.2.17 | Supply and Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells | |||
a | Up to 14 A | 1 No | 1200 | ||
b | 15 to 20 A | 1 No | 1600 | ||
c | 21 to 30 A | 1 No | 2300 | ||
d | 31 to 40 A | 1 No | 2600 | ||
372 | ELEC-6.2.18 | Supply and Fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL | |||
a | Non luminous type | 1 No | 95 | ||
b | Luminous type | 1 No | 130 | ||
6.3 | SUB STATION EQUIPMENT AND TRANSFORMERS | ||||
373 | ELEC-6.3.1 | Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: | 1 No | 24000 | |
(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) | |||||
(ii) Provision for fixing of combined CT PT Set (To be supplied by DISCOMs) | |||||
(iii)TT Block | |||||
(iv) 6mm Bakelite sheet on all sides. | |||||
ELEC-6.3.1a | Supply, Transportation, Installation and Commissioning of 11 KV, 630A, 25 KA Outdoor type Load Break Switch as detailed below with suitable CC foundation and 2 Nos GI pipe earthing with brick massonry chambers etc complete for finished item of work. a) Load break switch: 11KV,630A, 25 KA with fuse trip, earth switch, manually operated spring chargesd mechanis with 2 no + 2 NC. b) HT HRC fuse upto 63A - 3 nos. c) Bus bar connection. d) Indication lamps. e) Manual trip Push buttion. Make:ABB/ Megawin/Amara Raja/L&T |
120000 | |||
33 KV HT Panel (drawout type) | |||||
374 | ELEC-6.3.2 | Supply, Installation, Testing and Commissioning of indoor type floor mounted metal clad, 33 KV 800A VCB Panel with 3 Nos. VCBs suitable for 50Hz 3-phase system, suitable for 31.5kA/3sec short circuit withstand capacity & 31.5kA/1sec Internal Arc capacity. Switchgear Panel enclosure of sheet steel preferably Aluzinc, dust tight, vermin proof, totally enclosed cubicle floor mounting, free standing type with single break, horizontally drawout type breaker with trip free mechanism as per latest standard i.e. IS/IEC 62271-200 as amended up to date and as per Technical specifications, IP4X for VCB Panel enclosure. Switchgear Panel shall be electrically & mechanically interlocked as per IEC 62271-1, full voltage insulated copper Busbar with heat shrinkable sleeving, complete with suitable metering & protection devices, breaker featured with mechanical ON-OFF indicator with hand trip device and all accessories such as shunt trip coil, motorized & manually operated spring charging mechanism, emergency trip push buttons, auxiliary switch of 2NO + 2NC, interconnections, space heaters, panel earthing etc. and equipped with following switchgear and accessories including connection suitable for 3x185 to 3x 400 sqmm XLPE 33 kV cable (cable entry from bottom) to be connected through heat shrinkable jointing material etc as required. (Note - Cost of end termination not included in this item.) Makes:ABB/Schneider/Seimens/Kirlos kar/Amara Raja/Megawin/L&T |
1No | 2655000 | |
INCOMER 1 No. each comprising the following | |||||
1 No. 800 Amp. VCB. 31.5KA | |||||
1 No. Integral Earth switch for line side earthing | |||||
3 No. dual core CTs 600A/1/1A of 7.5VA burden max and accuracy Class 0.5 for metering and class 5P10 for protection |
|||||
3 No. Cast Resin 33000V/v3/110V/v3/110V/v3 PT Class 0.5/3P accuracy and 30VA burden max with and protection fuses / MCB. | |||||
1 No. Digital voltmeter with selector switch. | |||||
1 No. Digital Ammeter with selector switch. | |||||
1 No. Microprocessor based numerical relays with O/L, E/F and S/C protection with Integrated Arc sensing feature alongwith trip/lockout / antipumping / aux. relays. | |||||
1 No. Multi-function meter. | |||||
Set of MCBs for Panel AC/DC | |||||
Set of MCBs for Main AC/DC | |||||
Set of Indication lamps LED types | |||||
TNC Switch, L-R Switch, Pushbuttons for ON-OFF | |||||
OUTGOING 2 Nos. each comprising the following | |||||
1 No. 800 Amp. VCB.31.5KA | |||||
1 No. Integral Earth switch for line side earthing | |||||
3 No. dual core CTs 300A/1/1A of 7.5VA burden max and accuracy Class 0.5 for metering and class 5P10 for protection |
|||||
1 No. Digital Ammeter with selector switch. | |||||
1 No. Microprocessor based numerical relays with O/L, E/F and S/C protection with Integrated Arc sensing feature alongwith trip/lockout / antipumping / aux. relays. | |||||
Set of MCBs for Panel AC/DC | |||||
Set of Indication lamps LED types | |||||
TNC Switch, L-R Switch, Pushbuttons for ON-OFF | |||||
11KV HT Panel (drawout type) | |||||
375 | ELEC-6.3.3 | Supply, Installation, Testing and Commissioning of indoor type floor mounted metal clad, 11 KV 800A VCB Panel with 3 Nos. VCBs suitable for 50Hz 3-phase system, suitable for 26.3kA/3sec short circuit withstand capacity & 26.3kA/1sec Internal Arc capacity. Switchgear Panel enclosure of sheet steel preferably Aluzinc, dust tight, vermin proof, totally enclosed cubicle floor mounting, free standing type with single break, horizontally drawout type breaker with trip free mechanism as per latest standard i.e. IS/IEC 62271-200 as amended up to date and as per Technical specifications, IP4X for VCB Panel enclosure. Switchgear Panel shall be electrically & mechanically interlocked as per IEC 62271-1, full voltage insulated copper Busbar with heat shrinkable sleeving, complete with suitable metering & protection devices, breaker featured with mechanical ON-OFF indicator with hand trip device and all accessories such as shunt trip coil, motorized & manually operated spring charging mechanism, emergency trip push buttons, auxiliary switch of 2NO + 2NC, interconnections, space heaters, panel earthing etc. and equipped with following switchgear and accessories including connection suitable for 3x185 to 3x 400 sqmm XLPE 11kV cable (cable entry from bottom) to be connected through heat shrinkable jointing material etc as required. (Note - Cost of end termination not included in this item.) Makes:ABB/Schneider/Seimens/Kirlos kar/Amara Raja/Megawin/L&T |
1No | 1345000 | |
INCOMER 1 No. each comprising the following | |||||
1 No. 800 Amp. VCB. 26.3KA | |||||
1 No. Integral Earth switch for line side earthing | |||||
3 No. dual core CTs 600A/1/1A of 7.5VA burden max and accuracy Class 0.5 for metering and class 5P10 for protection |
|||||
3 No. Cast Resin 11000V/v3/110V/v3/110V/v3 PT Class 0.5/3P accuracy and 30VA burden max with and protection fuses / MCB. | |||||
1 No. Digital voltmeter with selector switch. | |||||
1 No. Digital Ammeter with selector switch. | |||||
1 No. Microprocessor based numerical relays with O/L, E/F and S/C protection with Integrated Arc sensing feature alongwith trip/lockout / antipumping / aux. relays. | |||||
1 No. Multi-function meter. | |||||
Set of MCBs for Panel AC/DC | |||||
Set of MCBs for Main AC/DC | |||||
Set of Indication lamps LED types | |||||
TNC Switch, L-R Switch, Pushbuttons for ON-OFF | |||||
OUTGOING 2 Nos. comprising the following | |||||
1 No. 800 Amp. VCB. 26.3KA | |||||
1 No. Integral Earth switch for line side earthing | |||||
3 No. dual core CTs 300A/1/1A of 7.5VA burden max and accuracy Class 0.5 for metering and class 5P10 for protection |
|||||
1 No. Digital Ammeter with selector switch. | |||||
1 No. Microprocessor based numerical relays with O/L, E/F and S/C protection with Integrated Arc sensing feature alongwith trip/lockout / antipumping / aux. relays. | |||||
Set of MCBs for Panel AC/DC | |||||
Set of Indication lamps LED types | |||||
TNC Switch, L-R Switch, Pushbuttons for ON-OFF | |||||
Oil Immersed TRANSFORMERS | |||||
376 | ELEC-6.3.4 | Supply and Transportation of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 33 KV as per energy efficiency level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC) etc., complete and as per the following continuous rating Make:ABB/ALSTOM/SEIMENS/Kirloskar/Voltamp/ Esennar/KPEL |
|||
a | 630 KVA | 1 No | 980000 | ||
b | 1000 KVA | 1 No | 1250000 | ||
c | 1250 KVA | 1 No | 1500000 | ||
d | 1600 KVA | 1 No | 1860000 | ||
e | 2000 KVA | 1 No | 2300000 | ||
377 | ELEC-6.3.5 | Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONANtype , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC) +10% to -10%, etc., complete and as per the following continuous rating Make:Schneider/Kirloskar/Voltamp/ Esennar/ Toshiba/ KPEL/ Powertech |
|||
a | 100 KVA | 1 No | 325500 | ||
b | 160 KVA | 1 No | 550000 | ||
c | 250 KVA | 1 No | 650000 | ||
d | 315 KVA | 1 No | 800000 | ||
e | 500 KVA | 1 No | 1050000 | ||
f | 630 KVA | 1 No | 1130000 | ||
g | 1000 KVA | 1 No | 1480000 | ||
Dry Type transformers | |||||
378 | ELEC-6.3.6 | Supply ,Transportation of cast Resin (Dry Type) indoor type copper double wound 33KV/0.433 KV, Three Phase 50 HzTransformers desingned and manufactured as per IS 11171/IEC 60726 , ANSI and NEMA Standards with all standard fittings,connected Delta on Primary side and Star on Secondary side with additional neutral brought out on load side 33000/433V with HV off load tap changing +5% to -15% temperature rise by the resistance 90 degrees with terminal arrangement Cable box on HV side and Bus duct on LV Side with off circuit Tap links etc.,, complete Make:ABB/ALSTOM/SEIMENS/Crompton/Kirloskar/Voltamp/ Esennar | |||
a | 1000 KVA | 1 No | 2650000 | ||
b | 1250 KVA | 1 No | 3300000 | ||
c | 1600 KVA | 1 No | 3990000 | ||
d | 2000 KVA | 1 No | 4800000 | ||
e | 2500 KVA | 1 No | 5400000 | ||
379 | ELEC-6.3.7 | Supply ,Transportation of cast Resin (Dry Type) indoor type copper double wound 11KV/0.433 KV, Three Phase 50 HzTransformers desingned and manufactured as per IS 11171/IEC 60726 , ANSI and NEMA Standards with all standard fittings,connected Delta on Primary side and Star on Secondary side with additional neutral brought out on load side 11000/433V with HV off load tap changing +5% to -15% temperature rise by the resistance 90 degrees with terminal arrangement Cable box on HV side and Bus duct on LV Side , with off circuit Tap links etc.,, complete . Make:ABB/ALSTOM/SEIMENS/Crompton/Kirloskar/Voltamp/ Esennar |
|||
a | 250 KVA | 1 No | 651000 | ||
b | 315 KVA | 1 No | 756000 | ||
c | 500 KVA | 1 No | 918000 | ||
d | 630 KVA | 1 No | 1102500 | ||
e | 750 KVA | 1 No | 1260000 | ||
f | 1000 KVA | 1 No | |||
6.4 | MAINTENANCE AND REPAIRS OF TRANSFORMERS | ||||
380 | ELEC-6.4.1 | Carryout routine maintenance, servicing and testing of 630A to 1000A L.T.ACB by cleaning fixed contacts, moving contacts and arcchutes including servicing and putting the ACB in perfect working condition after detting all relay and ON, OFF mechanism etc done with only manufacturing companies | 1 No | 5000 | |
381 | ELEC-6.4.2 | Carryout routine maintenance and servicing of LT.Cubical pannel board having approximately 15 to 22 Nos of switches cleaning with power blower and servicing the contacts, tightning the connection of incoming and outgoing cables, and checking the operating machanism for smooth functioning of switches and putting them in smooth working condition. | 1 No | 3000 | |
382 | ELEC-6.4.3 | Routine maintenance of transformer, including testing of insulation resistance, oil break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). | 1 No | 4500 | |
383 | ELEC-6.4.4 | Testing of Transformer oil for dielectric breakdown strength. | 1 No | 600 | |
384 | ELEC-6.4.5 | Removing the existing transformer from the plinth / Pole and refixing the standby transformer of following capacity including connections etc., complete…………. | |||
a | up to 315 KVA | 1 No | 3500 | ||
b | 500 / 1000 KVA | 1 No | 4500 | ||
385 | ELEC-6.4.6 | Replacing old and unserviceable gasket of top cover plate of transformer having following capacity. -………… | |||
a | up to 315 KVA | 1 No | 750 | ||
b | 500 / 1000 KVA | 1 No | 1000 | ||
386 | ELEC-6.4.7 | Replacing old and unserviceable gasket of bushing for the following Transformer capacity. -…………. | |||
a | up to 315 KVA HT, | 1 No | 350 | ||
b | 500 / 1000 KVA HT, | 1 No | 750 | ||
c | up to 315 KVA LT, | 1 No | 900 | ||
d | 500 / 1000 KVA LT, | 1 No | 1500 | ||
387 | ELEC-6.4.8 | Replacement the H T / L. T burntout winding coils of distribution transformer including rewinding, varnishing and vaccuming etc.,duly retaining the removed burnt winding coils by the Contractor / Firm- ……. | |||
a | For copper coils | 1 Kg | 600 | ||
b | For aluminium coils | 1 Kg | 400 | ||
387 | ELEC-6.4.9 | Insulating HT / LT copper / aluminium coils for Transformers. | 1 Kg | 325 | |
388 | ELEC-6.4.10 | Painting to transformer with 2 coats Zinchromate red oxide duly scraping existing paint followed by 2 coats of hammerton grey paint etc., complete. -………. | |||
a | Upto 500 KVA | 1 No | 3500 | ||
b | 630 / 1000 KVA | 1 No | 4500 | ||
389 | ELEC-6.4.11 | Replacing for distribution Transformer by new one. |
|||
a | H.T bushing | 1 No | 350 | ||
b | H.T bushing with metal parts | 1 No | 400 | ||
c | L.T bushing Upto 315 KVA | 1 No | 200 | ||
d | L.T bushing 500 / 1000 KVA | 1 No | 250 | ||
e | L.T bushing rod with metal parts up to 315 KVA | 1 No | 500 | ||
f | L.T bushing rod with metal parts 500/1000 KVA | 1 No | 1850 | ||
390 | ELEC-6.4.12 | Drying the repaired transformer with appropriate heat / air of following capacity of transformers. ……..- | |||
a | Upto 315 KVA | 1 No | 4400 | ||
b | 500 / 1000KVA | 1 No | 5500 | ||
391 | ELEC-6.4.13 | Loading, transportation and Unloading of transformer from site to Workshop or vice verse. ……… | |||
a | Upto 500 KVA | 1 No | 4500 | ||
b | 630 / 1000 KVA | 1 No | 7000 | ||
392 | ELEC-6.4.14 | Supply of new and tested transformer oil as per IS-335 - 1972 (per Ltr) | 1 Ltr | 120 | |
393 | ELEC-6.4.15 | Filteration of transformer oil as per ISS specifications filters to dielectric strength above 40KV …….. | |||
a | at site. (per Ltr) excluding transportation | 1 Ltr | 10 | ||
b | at workshop (per Ltr) | 1 Ltr | 7 | ||
6.5 | OVERHEAD LINES& LINE MATERIALS | ||||
394 | ELEC-6.5.1 | Supply and transportation of PSCC Poles | |||
a | 8.0 Mtr ,Working load-140 Kgs | 1No | 2150 | ||
b | 8.0 Mtr ,Working load-200 Kgs | 1No | 2275 | ||
c | 9.1 Mtr ,Working load-280 Kgs | 1No | 4150 | ||
395 | ELEC-6.5.2 | Supply and transportation of 9 mtr length RS Joist Poles | |||
f | 150 x 75 mm(Wt of the pole-140 Kgs) | 1No | 8600 | ||
g | 175 x 85 mm(Wt of the pole-215Kgs) | 1No | 13250 | ||
h | 150 x 150 mm(Wt of the pole-333 Kgs) | 1No | 20500 | ||
396 | ELEC-6.5.3 | Supply and errection of GI stay set of dia including stay clamps , turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc.,complete |
|||
a | 20mm,2.4 mtr long stay rod and anchor plate 380mmx380mmx6.4mm | 1 set | 1850 | ||
b | 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm | 1 set | 1400 | ||
397 | ELEC-6.5.4 | Supply and fixing of 11KV -V- cross arms with duly welded with necessary clamping arrangements etc., complete |
|||
a | 75x40 mm MS channel including 4 nos 50 x 50 x6 mm packing plates (9 Kgs) | 1 No | 1200 | ||
b | 65 x65 x6 MS angle (8.2 Kgs) | 1 No | 850 | ||
398 | ELEC-6.5.5 | Supply and fixing of LT 3 phase 4 wire cross arm of length 3' 8" with……. and necessary clamping arrangements ,cutting ,drilling and welding etc., complete | |||
a | 50 x 50 x6 mm MS angle ( wt 5.75 Kgs) | 1 No | 415 | ||
b | 65 x65 x6 MS angle (wt 7 Kgs) | 1 No | 490 | ||
399 | ELEC-6.5.6 | Supply and fixing of LT 3 phase 5 wire cross arm of length 4' 5" with……. and necessary clamping arrangements ,cutting ,drilling and welding etc., complete | |||
a | 50 x 50 x6 mm MS angle ( wt 7.30Kgs) | 1 No | 535 | ||
b | 65 x65 x6 MS angle (wt 9.60 Kgs) | 1 No | 675 | ||
400 | ELEC-6.5.7 | Supply and fixing of LT single phase 3 wire cross arm with 50 x 50 x6 mm MS angle of 2' 5" ( wt 4.20 Kgs ) and necessary clamping arrangements ,cutting ,drilling and welding etc., complete |
330 | ||
401 | ELEC-6.5.8 | Supply and fixing of 11 KV pin Insulator (IS 731/1971 ) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., | each | 200 | |
402 | ELEC-6.5.9 | Supply and fixing of LT pocelain pininsulator as per IS 1447-1997 suitable for working voltage 1100 V including all accessories like Hot dip GI spindle and nuts etc., |
|||
a | 100 x 65 mm | each | 80 | ||
b | 100 x 85 mm | each | 90 | ||
403 | ELEC-6.5.10 | Supply and fixing of LT pocelain shackle insulator as per IS 1443- 1979 suitable for working voltage 1100 V including all accessories like Hot dip GI spindle and nuts etc., |
|||
a | 75 x 90 mm | each | 140 | ||
b | 100 x 110 mm | each | 170 | ||
404 | ELEC-6.5.11 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure | each | 2500 | |
405 | ELEC-6.5.12 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 nos 24 KV /22 KV post Insulators( IS 5350, Hot dipped Hard ware, fuse wire of required size etc., complete |
each | 5500 | |
406 | ELEC-6.5.13 | Supply and fixing of 11 KV danger plates on the existing poles | each | 100 | |
407 | ELEC-6.5.14 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade,gang operated ,Hozizontal type,operating mechanism with GI spring loaded reverse loop type fixed contact,solid HD electrolytic copper tubular moving contact with silver/Nicle plated at end points,9 Nos post insulators of 12 Kv(IS 2594 and IS 5350) ,Hot Dip galvenizing hardware,GI pipe,Nuts and bolts etc., complete., | each | 18000 | |
408 | ELEC-6.5.15 | Supply and Transportation of Over Head …………. Conductor as per IS 398 (PART - II) : 1996 | |||
a | 7/3.55 ACSR Rabbit (214 Kg/KM) | 1KM | |||
b | 7/2.59 ACSR weasel (128 Kg/KM) | 1KM | |||
c | 7/2.11 ACSR squirrel (85 Kg/KM) | 1KM | |||
d | 100 sqmm AAA | 1KM | 50953 | ||
e | 55 sqmm AAA | 1KM | 29490 | ||
f | 34 sqmm AAA | 1KM | 17685 | ||
409 | ELEC-6.5.16 | Supply and errecting fencing section having size 2045 mt height from ground level and 1.2 mt width by using angle iron size 50 x50 x6 mm errected in cc foundation 15 x15x40 cm deep . The section of the frame shall be fitted with flat iron support of size 25 x 6 mm on top , bottom an dmid way and chain link jolley of 3.26 mm dia /10 SWG GI hard wire mesh of 50 x50 mm to the angle iron at every distance of 30 cm , by iron studs complete duly painted with one coat of red oxide and 2 coats of aluminium paint, | 1 No | As per DATA | |
410 | ELEC-6.5.17 | Supply and errecting double leaf hinged door each 150 cm in width and 180 cm in height using 40 mm dia B grade ISI mark GI pipe from all 4 sides with necessary bends and cross supports of angle iron 45 X45 X5 mm with the door leaf covered with chain links jolley 50 X 50 mm made from 3.26 mm dia/10 SWG Gi wire with necessary flat iron covering all round with necessary no of spikes of size 10 mm dia at top and bottom at 150 mm apart to match the height of fencing. The door shall have latches and side channel of 100 X50 X5 mm regidly welded for providing locking arrangement Godrej/Navtal make medium size lock with duplicate keys, fencing completely errected and painted with anti corrosive red oxide paint and 2 coats of prescribed enamel paint/silver paint. The Channel iron of size 150X75 mm by 2.5 mtr long shall be provided and errected at both sides of gate. |
1 No | As per DATA | |
411 | ELEC-6.5.18 | Supply and errecting 50 X50X6 mm angle iron corner support 0.5 mt way from the fence supports fixed at the middle fencing frame and other side in cc foundation 15 X15X 40 cm complete duly painted with 1 coat of red oxide and 2 coats of alluminum paint. | 1 No | As per DATA | |
412 | ELEC-6.5.19 | Providing and spreading HBG metal of size 40 mm size for 100 mm depth above the ground level. | As per DATA | ||
ELEC-6.5.20 | Providing transformer plinth 1.2 x 1.2 x 1.5 mtr in size with necessary excavation in ground at the bottom with 150mm thick 1:2:4 cement concrete raft at the bottom and top and 225mm thick wall constructed in stone masonry and remaking hallow portion shall be filled with stone chips duly plastered 20mm thick outsides including watering etc., complete. | 1 No | 10000 | ||
ELEC-6.5.21 | Providing CTPT plinth 600mm x 600mm x 2.1 mtr in size with necessary excavation in ground at the bottom with 150mm thick 1:2:4 cement concrete raft at the bottom and top duly plastered 20mm thick outsides including watering etc., complete. | 1 No | 6000 | ||
6.6 | LIGHTENING PROTECTIVE SYSTEM | ||||
Advanced LPS | |||||
ELEC-6.6.1 a | Supply of ESE Air Terminal of external wide area of protection system based on proactive Early Steamer Emission (ESE) Technology manufactured in accordance with NFC 17-102:2011, is made of high-quality, non corrosive and weather resistant XL-304 Stainless Steel Having triggering advance t = 30µs, Protection Radius ranging from 48 Meters in Level-I to 71 Meters in Level-IV when installed on a 5 Meters Mast. ESE terminal is capable to withstand Current Impulses of 40kA (5 Shots of 8/20µs wave shape) and having capturing rod dia of 25mm. Make : THUNDERGUARD(EARTHPLUS)/ KALRE/ NIMBUS / FOREND |
1 No | 95000 | ||
ELEC-6.6.1 b | ![]()
|
1 No | 100000 | ||
413 | ELEC-6.6.1 c | ![]()
|
1 No | 114000 | |
414 | ELEC-6.6.2 | Installation and commissioning of advanced lighting protection systems which includes 1. Laying of CC Bed 2. Installation of Lighting Rod 3. Laying of Down conductor 4. Installation of Counter 5. Installation of GI Mast with stay wire. 6. Installation of Earth Electrodes 7. Interconnection between the |
1 No | 29000 | |
Electrodes 8. Termination of down conductor to earth bus etc complete. |
|||||
415 | ELEC-6.6.3 | Supply of 6 Digit Electronic/Mechanical counter Make: EARTHPLUS (THUNDER GUARD) / NIMBUS / KALRE / FOREND | 1 No | 15000 | |
416 | ELEC-6.6.4 | Supply of G.I mast of 5 Meters length, 50 mm Dia, with FRP Collar (Insulating Bush) Base Plate & Complete Fitting Accessories with Supporting Guy Wire (Stay Wires) and all fitting accessories | 1 Set | 6000 | |
418 | ELEC-6.6.5 | Supply of IEC 62561-7 compliant Eco- friendly, Maintenance free, anti- corrosive, lead-free, super conductive, mineral based high-grade earthing compound, To enhance soil conductivity. With resistance <0.12 ohms-meter, Sulphur Free, Should be tested as per IEC-62561-7 for resistance Toxic Elements, Leachable elements etc. 25 Kg Bag Make: EARTHPLUS /CIRPROTEC / INDALAC / INGESCO |
1 No | 2200 | |
419 | ELEC-6.6.6 | Supply of Bentonite Moisture Retaining Powder 30 Kg Bag |
1 No | 170 | |
420 | ELEC-6.6.7 | Supply of Concrete Earth Pit of Dimensions: Width: 320 mm, Length: 320 mm, Height: 192mm, Weight 30 Kgs, Load bearing Capacity: 5000 Kgs | 1 No | 1500 | |
CONVENTIONAL LPS AS PER IS/IEC 62305 | |||||
Air Terminal | |||||
421 | ELEC-6.6.8 | Supply, installation, testing and commissioning of 8 mm Aluminum Round Conductor complete as per requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) |
1 RM | 90 | |
422 | ELEC-6.6.9 | Supply, installation, testing and commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance |
each | 50 | |
423 | ELEC-6.6.10 | Supply, installation, testing and commissioning of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost- resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. |
each | 130 | |
424 | ELEC-6.6.11 | Supply, installation, testing and commissioning of Fang Fix Junior system - Inclusive of Al intrception rod of 1Mtr length(10mm dia ) , Quick mounting of the interception rod in the base using plug technology | each | 1650 | |
425 | ELEC-6.6.12 | Supply, installation, testing and commissioning of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts | each | 132 | |
426 | ELEC-6.6.13 | Supply, installation, testing and commissioning of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU.Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high- grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). |
each | 395 | |
DOWN CONDUCTOR | |||||
427 | ELEC-6.6.14 | Supply, installation, testing and commissioning of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 | 1 RM | 90 | |
(VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) |
|||||
428 | ELEC-6.6.15 | Supply, installation, testing and commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance |
each | 50 | |
429 | ELEC-6.6.16 | Supply, installation, testing and commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer | each | 310 | |
430 | ELEC-6.6.17 | Supply, installation, testing and commissioning of Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. | each | 16500 | |
6.7 | EARTHING | ||||
431 | ELEC-6.7.1 | Providing earth electrode of low carbon steel rod, UL listed of 17.2 mm dia, 3 Mtr long, coated with copper of 254 microns thickness, CPRI tested for short time current withstand test of 25 kA, coating thickness, environmental test (Salt Mist Test), Bend test, Tensile strength, Yield / tensile ratio, Electrical Resistivity test, complete with clamps and 2 bags of Earthplus ULTRA high grade earthing compound IEC 62561-7 complaint Eco-friendly, Maintenance free, anti corrosive, lead-free, super conductive, mineral based high-grade earthing compound, to enhance soil conductivity. With resistance <0.20 ohms-meter, should be leach proof & sulphur free complete with earth inspection chamber of dimensions : Width : 320 mm x 320 mm, Height : 192 mm, Weight : 30 Kgs, Load bearing capacity : 5000 Kgs |
1 No | 9500 | |
432 | ELEC-6.7.2 | Providing earthling as per IS 3043 with perforated 3 mtr long 40 mm dia B class GI pipe including all accessories like nuts bolts reducer,nipple, wire meshed funnel andCCfinished chamber covered with hinged type with CI cover ,CI frame of size 300 X 300 mm and embodying the pipe complete with alternate layers of salt and coke /charcoal/bentonite powder testing earth resistance as required etc., complete |
1 No | As per DATA | |
433 | ELEC-6.7.3 | Providing earthling as per IS 3043 with GI earth plate of size 600 x600 x 6 mm by embodying 3 to 4 mtr nelow the ground level with 40 mm dia GI B class perforated pipe including all including all accessories like nuts bolts reducer,nipple, wire meshed funnel andCCfinished chamber covered with hinged type with CI cover ,CI frame of size 300 X 300 mm and embodying the pipe complete with alternate layers of salt and coke /charcoal/bentonite powder testing earth resistance as required etc., complete |
1 No | As per DATA | |